    2JZ-JM mechanical diaphragm metering pump installation diagram:

    2JZ-JM mechanical diaphragm metering pump parameter table :

    Installation requirements:
    1. The pump should be installed on a specially prepared concrete foundation or iron cast platform, and fixed with anchor bolts after correction. The concrete foundation should be 50 to 100 mm higher than the ground.
    2. The diameter of the suction and discharge pipes should be no less than the diameter of the inlet and outlet pipes, and the suction pipe should be shortened as much as possible. If the suction line is too long or there are too many elbow joints, NPSHa calculations should be performed to meet the necessary net positive suction head requirements.
    3. The connecting pipelines should be equipped with measuring instruments, such as pressure gauges (prepared by the user).
    4. The end of the suction pipe should be equipped with a filter device (prepared by the user).
    5. The discharge pipeline should be equipped with a safety valve or safety relief valve (prepared by the user). If you need to reduce the outlet pressure pulsation, a pressure stabilizing device can be installed on the discharge line close to the pump.
    6. The electrical control equipment should be installed at the working location of the pump as much as possible according to the usage conditions. The electrical control equipment should be equipped with control switch protection devices corresponding to the transported medium to ensure safety.
    7. For multi-joint combination pumps (piston type or diaphragm type), for the same machine base and the same specifications, the piping should be arranged according to the process pressure level, starting from the motor as the basic point, and the pressures are arranged in order from high to low; for different machine bases, it is different The combination of specifications has been installed from large to small, and the user only needs to connect the pipes.